Maximize energy production, safety, and achieve significant savings in Balance of System (BoS) and Operations and Maintenance (O&M) costs with our range of innovative and lightweight three phase inverters. Our three phase ground mount, rooftop, carport inverters are ideal for driving more power and more safety into broad range of commercial projects: Deliver up to 10% more energy by pairing with our Power Optimizers, Reduce BoS costs by 50% with longer strings and flexible design, Maximize system uptime: pinpoint issues with module-level monitoring, Instill confidence with advanced safety, such as arc fault protection and rapid shutdown, There's a reason why 50% of Fortune 100 companies have SolarEdge on their roofs. Ensuring peace of mind is no problem with our built-in advanced SafeDC™ features, including: Fully integrated rapid shutdown, Arc-fault detection & prevention, Surge protection. Get more done in less time - and minimize Operations & Maintenance (O&M)costs - with innovative, flexible design: Reduce time, cost and labor with a simple 2-person installation through lightweight, modular design. Synergy Manager unit provides easy access for DC disconnect during maintenance. Higher system uptime with independently working Synergy Unit. Supports 3-wire connection and accommodates no-neutral or delta configurations.
Features
- Up to 175% oversizing
- Only 70.5 lbs. means a simpler install
- Industry-Leading, extendable 12-year warranty, extendable to 25 years
- Fully integrated rapid shutdown
- Arc-fault detection & prevention
- Surge protection
- Specifically designed to work with power optimizers
- Quick and easy inverter commissioning directly from a smartphone using SolarEdge SetApp
- Fixed voltage inverter for superior efficiency and longer strings
- Built-in type 2 DC and AC Surge Protection, to better withstand lightning events
- Small, lightest in its class, and easy to install outdoors or indoors on provided bracket
- Integrated arc fault protection and rapid shutdown for NEC 2014, 2017, and 2020, per article 690.11 and 690.12
- Built-in module-level monitoring with Ethernet, wireless or cellular communication for full system visibility
- Integrated Safety Switch
- UL1741 SA and SB certified, for CPUC Rule 21 grid compliance
-
Three phase inverters for the 120/208V grid
Specifications
-
Width: 12.5 in
-
Height: 31.8 in
-
Depth: 11.8 in
-
Maximum Input Voltage: 840-1000 VDC
-
Transformer-Less, Ungrounded: Yes, Input
-
Reverse-Polarity Protection: Yes, Input
-
Ground Fault Isolation Detection: 167 kOhm Sensitivity (Input)
-
Maximum Input Short-Circuit Current: 55 A
-
CEC Weighted Efficiency: 98.5% Input
-
Rated AC Output Power: 40000 W
-
Maximum AC Power Output: 40000 W
-
AC Frequency Range (Min-Nom-Max): 59.3-60-60.5 Hz (Output)
-
GFDI Threshold: 1 Output
-
Total Harmonic Distortion (THD): +/-0.85 to 1 (Output)
-
Utility Monitoring, Islanding Protection, Country Configurable Thresholds: Yes, Output
-
Typical Nighttime Power Consumption: <4 W Input
-
AC L-L Output Voltage Range (Min-Nom-Max): 422.5-480-529 VAC
-
AC L-N Output Voltage Range (Min-Nom-Max): 244-277-305 VAC
-
Maximum DC Power (Module STC): 700000 W Input
-
Continuous Output Current (Per Phase): 48.25 A AC Output
-
Maximum Input Current: 48.25 A
-
Supported Communication Interfaces: 2 x RS485, Ethernet
-
Inverter Commissioning: With the SetApp Mobile Application using built-in Wi-Fi Access Point for Local Connection
-
Rapid Shutdown: NEC 2014-2023 per articles 690.11 and 690.12: Yes
-
AC Output Conduit Size/AWG Range: 3/4 in/1 in/6-10 AWG
-
DC Input Conduit Size/AWG Range: 3/4 in or 1 in/6-10 AWG
-
Phase: 3
-
Noise Rating: <62 dBA
-
Cooling: Fans (User Replaceable)
-
RS485 Surge Protection Plug-in: Built-In
-
AC/DC Surge Protection: Built-In
-
DC Fuses (Single Pole): 25 A, Built-In
-
Smart Energy Management: Export Limitation
-
DC Disconnect: Integrated
-
Number of DC Inputs Pairs: 4
-
Mounting Type: Bracket
-
Operating Temperature: -40 to 140°F
-
Protection Rating: NEMA 3R
-
Standards: UL1741, UL1741 SA, UL1741 SB, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07, IEEE1547-2018, Rule 21, Rule 14 (HI), FCC part15 class A, CSAcUS
-
Warranty: 12-20 Years
-
Weight: 78.2 lb