OutBack Power's EnergyCell™ FLA batteries are designed for residential or light-commercial off-grid renewable energy power demands. Optimized to work seamlessly with OutBack power conversion equipment, these batteries are a perfect addition to the OutBack single-brand system solution. Built for rugged, deep cycle cell construction, these batteries deliver superior performance and longevity. EnergyCell FLA is an innovative solution specially designed for residential or light-commercial, off-grid renewable power demands. These batteries are built using a robust cell construction and heavy-duty internal connectors and post structures, maximizing life expectancy and enabling unmatched electrical efficiency and durability. In addition, the EnergyCell 525FLA offers a proprietary electrolyte level indicator that signal when watering service is required-making service easy and predictable. At the end of life, these batteries are 96% recyclable.
Features
- Designed for residential or light-commercial off-grid renewable energy power demands
- Rugged, deep cycle cell construction delivers superior performance and longevity
- Proprietary cell construction reduces water loss during charging service
- Additional fluid headspace above battery plate extends performance between watering service intervals
- Optimized to work seamlessly with OutBack Power conversion equipment
- Ideal use for deep cycling applications
- Up to1550 cycles @ 50% DoD
- Heavy-duty internal connectors and terminal
- post structures
- Built-in electrolyte level indicators (525FLA)
- Proprietary plate separators guard against short-circuit
- BCI group sizes GC2 and 903
Specifications
- Number of Cells: 3
- Nominal Voltage Rating: 6 VDC
- Cycle Life (50% DoD): 1550
- Absorb Voltage (25 deg C): 7.26 VDC
- Absorb Time: 6.75 VDC
- Float Time: Absorb Time
- Equalize Charge Frequency: Equalize Charge Every 30 days, Systems that are Regularly Discharged below 50% of Stored Capacity Should be Equalized Every 14 days
- Re-Bulk Voltage2: 12/24/48 VDC
- Re-Float Voltage2: 12.5/25/50 VDC
- Maximum Charger Current Per Battery: 100 A
- Operating Temperature: -40 to 120 deg F
- Optimal Operating Temperature: 40-80 deg F
- Temperature Compensation Factor (Charging): +/-3 mV per deg C per cell
- Self-Discharge Time: Fully Charged Batteries that are Stored at a Temperature of 80 deg F (27 deg C) will Self-Discharge at a Rate of 3.5% per Week
- Terminal Type: Standard Type with Stainless Steel
- Terminal Hardware Initial Torque4: Stainless thread, 100 to 120 in-lb (11 to 14 Nm)
- Equalize Voltage: 7.74 VDC
- Specific Gravity: Full Discharge Specific Gravity (100% Depth of Discharge): 1.125
- Vent Cap: Bayonet
- PROeye™ Electrolyte Level Indicator: Yes
- Dimensions: 16.13 in x 7.19 in x 12.38 in
- Weight: 122 lb
Documents