The HUB system communications manager is the backbone of your networked OutBack power conversion system. The OutBack HUB communicates stacking, load share and power save on/off signals. Interconnection cabling is standard Ethernet CAT5 with RJ45 modular jacks. Through the use of a HUB, your system is completely coordinated and managed by the MATE.
Features
- Communication stacking
- Load share and power save on/off signals
- Standard interconnection cabling
- Ethernet CAT5 with RJ45 modular jacks
Specifications
-
Width: 8.3 in
-
Height: 6.9 in
-
Depth: 1.2 in
-
Commonly Used Module Pairings: 295-460 W (Input DC)
-
Module Compatibility: 60-Cell and 72-Cell PV Modules (Input DC)
-
Maximum Input DC Voltage: 58 V (Input DC)
-
Maximum Input DC Current: 10.2 A (Input DC)
-
Peak Power Tracking Voltage: 38-43 V (Input DC)
-
Operating Range: 18-58 V (Input DC)
-
Minimum/Maximum Start Voltage: 30 V/58 V (Input DC)
-
Maximum DC Short-Circuit Current (Module ISC): 15 A (Input DC)
-
Over Voltage Class DC Port: II (Input DC)
-
PV Array Configuration: 1 x 1 Ungrounded Array, No Additional DC Side Protection Required, AC Side Protection Requires Maximum 20 A Per Branch Circuit (Input DC)
-
Peak Output Power:
- 366 VA at 240 VAC (Output AC)
- 295 VA at 208 VAC (Output AC)
-
Maximum Continuous Output Power:
- 349 VA at 240 VAC (Output AC)
- 290 VA at 208 VAC (Output AC)
-
Nominal (L-L) Voltage/Range:
- 240 V/211-264 V at 240 VAC (Output AC)
- 208 V/183-229 V at 208 VAC (Output AC)
-
Maximum Continuous Output Current:
- 1.45 A at 240 VAC (Output AC)
- 1.39 A at 208 VAC (Output AC)
-
Nominal Frequency Rating: 60 Hz at 240 VAC (Output AC)
-
Extended Frequency Range: 47-68 Hz at 240 VAC (Output AC)
-
AC Short-Circuit Fault Current Over 3 Cycles: 5.8 Arms at 240 VAC (Output AC)
-
Maximum Units Per 20 A (L-L) Branch Circuit:
- 11 at 240 VAC
- 11 at 208 VAC
-
Over Voltage Class AC Port: III at 240 VAC (Output AC)
-
AC Port Backfeed Current: 18 mA at 240 VAC (Output AC)
-
Power Factor Setting: 1 at 240 VAC (Output AC)
-
Power Factor (Adjustable): 0.85 Leading to 0.85 Lagging (Output AC)
-
CEC Weighted Efficiency:
- 97% at 240 VAC
- 96.5% at 208 VAC
-
Ambient Temperature Rating: -40 to 60°C
-
Relative Humidity: 4-100% (Condensing)
-
Connector Type DC (IQ7A-72-2-US): MC4
-
Cooling: Natural Convection - No Fans
-
Approved For Wet Location: Yes
-
Degree of Pollution: PD3
-
Enclosure Rating: Class II Double-Insulated, Corrosion Resistant Polymeric Enclosure
-
Environmental Category/UV Exposure Rating: NEMA Type 6/Outdoor
-
Communication: Power Line Communication (PLC)
-
Monitoring:
- Enlighten Manager and MyEnlighten Monitoring Options Compatible with Enphase IQ Envoy
-
Number of Ports: 4 Plus MATE
-
Standards:
- UL Listed
- CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 cETLus Listed B, ICES-0003 cETLus Listed B, CAN/CSA-C22.2 NO. 107.1-01
- UL Listed as PV Rapid Shut Down Equipment and Conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC Conductors, When Installed According to Manufacturer's Instructions
-
Warranty: 25 Years
-
Weight: 2.38 lb
Documents