The Classic 150 MPPT charge controller is MidNite Solar's most popular model. It has arc fault, ground fault, free web monitoring, a graphics panel and Solar, Hydro and Wind Modes. The Classic 150 has a maximum output current of 96 A, an operating voltage of 150 V and works with 12 to 72 V battery systems. The FREE MidNite Solar local application enables you to monitor your Classics over your local network or the Internet. As with the whole Classic Line, the Classic 150 has MidNite's exclusive HyperVOC which extends VOC limits when needed.
Features
- Charges Lithium, Flooded Lead Acid, AGM And Virtually Any Other Chemistry
- Exclusive HyperVOC Extends VOC Limits
- Built In DC-GFP And Arc Fault
- Detector
- Solar, Wind And Hydro MPPT Modes
- To Ensure Proper Start Up And MPPT Operation, The Minimum Initial PV Input Voltage Should Be At Least 30% Higher Than The Highest Expected Battery Voltage
- Low Battery Voltage disconnect and re-connect of loads fully programmable with 2 auxiliary output to control external load disconnect/re-connect switch
- Hyper VOC standard all models - extended VOC range for cold climates
- Arc fault protection - standard on classic, 0.25 seconds detect and trip speed
- Ground fault protection - standard all models - resettable, no fuse to blow
Specifications
-
Nominal Battery Voltage: 72 V
-
Maximum Output Current:
- 96 A on 12 V
- 94 A on 24 V
- 86 A on 48 V
-
PV Open Circuit Voltage (VDC): 150 V
-
Power Conversion Efficiency: 98%
-
Maximum Standby Self Consumption: 2.8-4 W
-
Reverse Current at Night: Zero (Internal Relay for Reverse Current)
-
Type of Charging/Charging Regulation: Bulk, Absorb, Float & Equalization
-
Battery Voltage Regulation Set Points: 10-100 VDC
-
Equalization Charging: Adjustable Voltage & Duration, Manual or Auto
-
PV Reverse Polarity: Protected to Maximum VOC
-
Battery Reverse Polarity: Fully Protected
-
Battery Over Voltage: Fully Protected
-
Battery Short Circuit: Fully Protected
-
Battery Temperature Compensation:
- Automatic when BTS is Installed
- Adjustable mV per °C per 2 V Cell
-
Programmable Auxiliary Control Output:
- 2 Auxiliary Outputs
- Auxiliary 1: 12 V Out or Dry Connect
- Auxiliary 2: 12 V Out or Logic N
-
Graphic Display: Yes
-
Networking Cabling: Standard 4-Conductor Phone Cable, No Hub Needed
-
Communication: ModBus Openly Published over Ethernet & RS232
-
Remote Display:
- Display (MNGP) can be Relocated
- Second Display can be Added
-
Terminal Rating: 75°C
-
Internal Ready: All Models
-
Data Logging:
- 380 Days of Daily History
- 24 Hours of Data at 5-Minute Intervals
-
Operating Temperature: -40 to 50°C
-
Environmental Rating: IP30
-
Conduit Knockout:
- Single 1 in Conduit on Left & Right Sides
- Two 1 in Conduits on Bottom
- Two 3/4 in Conduits on Back
-
Standards: ETL Listed, CE Certified
-
Warranty: 5 Years
-
Dimensions: 14.9 in x 6 in x 4 in
-
Weight: 12 lb