The classic SL-150 MPPT charge controller is a simplified solar only version of the classic 150 with streamlined menus. the classic SL-150 has a graphics panel and ground fault but no arc fault or ethernet capabilities. the classic SL-150 has a maximum output current of 96 amps, an operating voltage of 150 volts and works with 12 to 72 volt battery systems. as with the whole classic line, the classic SL-150 has midnite's exclusive hypervoc which extends voc limits when needed.. with a streamlined menu, these solar only MPPT charge controllers are easy to setup and a breeze to install.
Features
- Exclusive HyperVOC Extends VOC Limits
- Built in DC-Ground Fault Protection
- Optional Battery Sensor for temperature correction on battery charging
- Type 1 environmental rating
- Low Battery Voltage disconnect and re-connect of loads fully programmable with 2 auxiliary output to control external load disconnect/re-connect switch
- Hyper VOC standard all models - extended VOC range for cold climates
- Arc fault protection - standard on classic, 0.25 seconds detect and trip speed
- Ground fault protection - standard all models - resettable, no fuse to blow
Specifications
- 
Nominal Battery Voltage: 72 V
- 
Maximum Output Current:
- 96 A on 12 V
- 94 A on 24 V
- 86 A on 48 V
 
- 
PV Open Circuit Voltage (VDC): 150 V
- 
Power Conversion Efficiency: 98%
- 
Maximum Standby Self Consumption: 2.8-4 W
- 
Reverse Current at Night: Zero (Internal Relay for Reverse Current)
- 
Type of Charging/Charging Regulation: Bulk, Absorb, Float & Equalization
- 
Battery Voltage Regulation Set Points: 10-100 VDC
- 
Equalization Charging: Adjustable Voltage & Duration, Manual or Auto
- 
PV Reverse Polarity: Protected to Maximum VOC
- 
Battery Reverse Polarity: Fully Protected
- 
Battery Over Voltage: Fully Protected
- 
Battery Short Circuit: Fully Protected
- 
Battery Temperature Compensation:
- Automatic when BTS is Installed
- Adjustable mV per °C per 2 V Cell
 
- 
Programmable Auxiliary Control Output:
- 2 Auxiliary Outputs
- Auxiliary 1: 12 V Out or Dry Connect
- Auxiliary 2: 12 V Out or Logic N
 
- 
Graphic Display: Yes
- 
Networking Cabling: Standard 4-Conductor Phone Cable, No Hub Needed
- 
Communication: ModBus Openly Published over Ethernet & RS232
- 
Remote Display:
- Display (MNGP) can be Relocated
- Second Display can be Added
 
- 
Terminal Rating: 75°C
- 
Internal Ready: All Models
- 
Data Logging:
- 380 Days of Daily History
- 24 Hours of Data at 5-Minute Intervals
 
- 
Operating Temperature: -40 to 50°C
- 
Environmental Rating: IP30
- 
Conduit Knockout:
- Single 1 in Conduit on Left & Right Sides
- Two 1 in Conduits on Bottom
- Two 3/4 in Conduits on Back
 
- 
Standards: ETL Listed, CE Certified
- 
Warranty: 5 Years
- 
Dimensions: 14.9 in x 6 in x 4 in
- 
Weight: 12 lb
Documents