The SE9kUS and SE14.4kUS inverters have a fixed input voltage of 400 VDC, while the SE10kUS, SE20kUS, and SE33.3kUS inverters operate with fixed input voltage of 850 VDC. The fixed input voltage from the optimizers allows for longer module string lengths, resulting in less wire line losses and fewer system components. These wall-mountable inverters are lightweight, and have built in module-level monitoring. They include an integrated code-compliant DC disconnect, Ethernet interface, and RS-485 serial port. All SolarEdge inverters are listed to UL 1741 and UL 1699B for the U.S.A. and Canada and are NEMA 3R rated. The inverters are rated for use from -4 F to 140 deg F temperatures. The SE14.4kUS and the SE33.3kUS inverters also come with three fused DC+ and DC- inputs, eliminating the need for a third-party fused combiner box. The optimizers automatically shut down the DC current and voltage when detecting excessive heat, or when the SolarEdge inverter is turned off or disconnected from the grid, to ensure installer and firefighter safety. The high fixed voltage of a SolarEdge commercial system enables longer DC strings to be wired, lowering installation, connection, and wiring costs over typical commercial string inverter systems. Monitoring through the SolarEdge monitoring portal can be enabled by connecting the inverter directly to an Internet router or switch, or using the wireless SolarEdge Zigbee Gateway Kit and Slave Modules. Commercial systems also can be equipped with the SolarEdge Environmental Sensors (irradiance, module and ambient temperature, and wind), as well as the Firefighter Gateway to improve safety in an emergency if needed or required.
Features
- Specifically designed to work with SolarEdge power optimizers
- Quick an easy inverter commissioning directly from a smartphone using the Solar Edge SetApp
- Superior efficiency (98.5%)
- Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12
- UL1741 SA certified, for CPUC Rule 21 grid compliance
- Built-in module-level monitoring
- Internet connection through Ethernet or Wireless
- Small, lightweight and easy to install outdoors or indoors on provided bracket
- Fixed voltage inverter for longer strings
- Integrated safety switch
-
Supplied with RS485 surge protection device, to better withstand lightning events
Specifications
-
Width: 12.5 in
-
Height: 30.5 in
-
Depth: 10.5 in
-
Maximum Input Voltage: 490/1000 VDC
-
Nominal DC Input Voltage: 420/840 VDC
-
Transformer-Less, Ungrounded: Yes, Input
-
Reverse-Polarity Protection: Yes, Input
-
Ground Fault Isolation Detection: 350 kOhm Sensitivity (Input)
-
Maximum Input Short-Circuit Current: 39 A
-
CEC Weighted Efficiency: 98.5% Input
-
Rated AC Output Power: 30000 W
-
Maximum AC Power Output: 30000 W
-
AC Frequency Range (Min-Nom-Max): 59.3-60-60.5 Hz (Output)
-
GFDI Threshold: 1 Output
-
Total Harmonic Distortion (THD): Utility Monitoring, Islanding Protection, Country Configurable Thresholds: Yes, Output
-
Typical Nighttime Power Consumption: <4 W Input
-
AC L-L Output Voltage Range: 422.5-480-529 VAC
-
AC L-N Output Voltage Range: 244-277-305 VAC
-
Maximum DC Power (Module STC): 40500 W Input
-
Continuous Output Current (Per Phase): 36.5 A AC Output
-
Maximum Input Current: 39 A
-
Supported Communication Interfaces: 2 x RS485, Ethernet
-
Inverter Commissioning: With the SetApp Mobile Application using built-in Wi-Fi Access Point for Local Connection
-
Rapid Shutdown - NEC 2014-2023: Yes, per articles 690.11 and 690.12
-
AC Output Conduit Size/AWG Range: 3/4 in Minimum/8-4 AWG
-
DC Input Conduit Size/AWG Range: 3/4 in Minimum/12-6 AWG
-
Phase: 3
-
Noise Rating: <55 dBA
-
Cooling: Fans (User Replaceable)
-
AC Output Line Connections: 3 Phase, 4 Wire/PE (L-1-L2-L3-N)
-
RS485 Surge Protection Plug-in: Built-In
-
Smart Energy Management: Export Limitation
-
Number of DC Inputs Pairs: 3
-
Operating Temperature: -40 to 140°F
-
Protection Rating: NEMA 3R
-
Standards: UL1741, UL1741 SA, UL1741 SB, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07, IEEE1547-2018, Rule 21, Rule 14 (HI), FCC part15 class A, CSAcUS
-
Warranty: 12-20 Years
-
Weight: 106 lb