200A passthrough, so there's no subpanel needed! This inverter is perfect for whole-home backup. Features and benefits include parallel stacking, grid sell, meter zero, time of use, smart load, AC coupling, & peak shaving. The Sol-Ark 15k Outdoor Case is a pre-wired system that contains the inverter, charge controller, and more, all in one package; no fuses, breakers, or combiner boxes necessary! With minimal additional hardware required, your install stays simple and low-cost. Sol-Ark inverters also do not have expensive battery restrictions like other solar inverters do, and can be used with a wide variety of 48V battery chemistries, from lead to lithium.
Features
- French cleat for easy installation
- Built-in solar array disconnect
- Remote Wi-Fi/Ethernet and local monitoring
- Outdoor rated NEMA 3R
- Battery agnostic
- 19.5 kW Solar input power
- 15 kW Output power off-grid
-
Full generator compatibility
Specifications
-
-
Width: 18.3 in
-
Height: 31.8 in
-
Depth: 10.9 in
-
Weight: 135 lb
-
Mounting Type: Wall
-
Enclosure Rating: IP65/NEMA 3R
-
Ambient Temperature Rating: -40 to 60°C
PV Input Data:
-
Maximum Allowed PV Power (STC): 19,500 W
-
Maximum PV Power Delivered to Battery & AC Outputs: 15,000 W
-
MPPT Voltage Range: 125-425 V
-
Startup Voltage: 125 V
-
Maximum DC Input Voltage: 500 V at 26 A
-
Maximum Operating Input Current Per MPPT: 26 A
-
Number of MPPT Trackers: 2
-
Number of PV Strings Per MPPT: 3
-
Maximum AC Coupled Input: 19,200 W
Battery Input Data (DC):
-
Battery Chemistry: Lead-Acid or Li-Ion
-
Nominal DC Voltage: 48 V
-
Operating Voltage: 43-63 V
-
Capacity: 50-9900 Ah
-
Maximum Battery Charge/Discharge Current: 275 A
-
Charging Controller: 3-Stage with Equalization
-
Grid to Battery Charging Efficiency: 96%
-
External Battery Temperature Sensor (BTS): Included
-
Current Shunt for Accurate %SOC: Included
-
External Gen Start Based on Voltage or %SOC: Included
-
BMS Communication: CANBus & RS485
AC Output Data:
-
Connection: 120/240/208V Split Phase
-
Continuous AC Power with PV: 15,000 W (62.5 A-L at 240 V)
-
Continuous AC Power from Batteries: 12,000 W (50 A-L at 240 V)
-
Total Harmonic Distortion (THD):
- Continuous AC Power with Grid or Generator: 48,000 W (200A L-L at 240 V)
- 24,000 W (200 A L-N at 120 V)
-
Grid Frequency: 50/60 Hz
-
Maximum Output Fault Current (5 sec): 94 A with PV
-
Maximum Output Fault Current (100 ms): 75 A without PV
-
Power Factor Output Range: ±0.9 to 1
-
CEC Efficiency: 96.5% (Peak 97.5%)
-
Design (DC to AC): Transformerless
-
Stackable: 12 Units
-
Idle Consumption Typical (No-Load): 90 W
-
Sell Back Power Modes: Limited to Household / Fully Grid-Tied
-
Response Time (Grid-Tied to Off-Grid): 5 ms
Safety and Protection:
-
PV DC Disconnect Switch (NEC 240.15): Integrated
-
Ground Fault Detection (NEC 690.5): Integrated
-
PV Rapid Shutdown Control (NEC 690.12): Integrated
-
PV Arc Fault Detection (NEC 690.11): Integrated
-
PV Input Lightning Protection: Integrated
-
PV String Input Reverse Polarity Protection: Integrated
-
AC Output Breaker (200 A): Integrated
-
200 A x 2 Battery Breaker/Disconnect: Integrated
-
Surge Protection: DC Type II / AC Type II
Communication and Monitoring:
- Wi-Fi & LAN Hardware Included
Certifications & Standards:
-
Electronics Certified Safety by SGS Labs to NEC & UL Specs:
- NEC 690.4B & NEC 705.4/6
- Grid Sell Back - UL1741-2010/2018, IEEE1547a-2003/2014
- FCC 15 cETLus Listed B
- UL1741SB, CA Rule 21, HECO Rule 14H
Warranty:
Documents